Product Overview
Part number 5.7616E3 is factory‑spec integrated 2‑in‑one Combi‑Cooler, combining oil cooler and compressed‑air aftercooler in single aluminum bar‑plate assembly for matched stationary Kaeser ASD‑BSD‑CSD oil‑injected rotary screw compressors.
This single compact heat exchanger handles two critical cooling loops at the same time:
1. Cool circulating compressor lubricant oil to maintain safe operating oil‑temperature;
2. Cool hot compressed air coming from air‑end, reduce compressed‑air temperature and condense water vapor for downstream dryer & filter system.
Critical field troubleshooting note: Compressor high‑temperature shutdown alarm does not automatically mean combi‑cooler is defective. Field technicians shall follow standard diagnostic sequence: inspect external fin clogging → cooling fan operation → thermostatic element condition → lubricant quality & oil filter status, before concluding cooler core internal leakage / blockage and ordering replacement part. Many overheating issues are caused by peripheral components instead of cooler itself.
Important hardware note: This is stationary screw compressor combi heat‑exchanger. Not designed for mobile construction compressor, turbine power‑generation equipment. No food‑grade / FDA‑H1 certification. Replacement is NOT plug‑and‑play. Work includes full oil draining, gasket renewal, air‑pocket venting and full‑load temperature validation after commissioning.
Combi‑cooler has two independent internal circuits (oil circuit / compressed‑air circuit). Damaged sealing gaskets can cause dangerous cross‑leak: compressor lubricant penetrates into compressed‑air flow and leads to heavy oil‑carry‑over into production pipeline.
Critical buying alert: Part‑number 5.7616E3 alone cannot guarantee perfect fitment. Even with similar outer dimension, internal flow channel, port and flange specification may differ according to compressor hardware revision. Always submit full compressor serial‑number plus photo of old combi‑cooler name‑plate for our technical cross‑verification before placing your order, avoid wrong‑part shipment and costly production downtime.

Customer Buying & Maintenance Priorities
Industrial buyers sourcing Kaeser combi cooler make purchasing decisions not purely based on price. These key practical concerns are fully addressed on this page:
1. Fitment accuracy risk: Same PN may contain internal flow‑channel revisions; serial‑number cross‑validation to prevent wrong‑part delivery.
2. Fault‑diagnosis logic: Avoid blind cooler replacement; complete checklist for high‑temperature alarm before ordering expensive combi‑cooler assembly.
3. Gasket set importance: Two‑circuit combi‑cooler requires complete gasket renewal; gasket failure may cause oil‑to‑air cross‑leakage.
4. Installation risk awareness: Full oil draining requirement; vent air‑pockets; avoid mechanical shock to fragile aluminum bar‑plate core.
5. Post‑replacement validation: Must monitor full‑load oil‑temperature and compressed‑air dew‑point after installation.
6. Warranty scope clarity: Manufacturing defect coverage; fouling, contamination, mechanical installation damage excluded; no onsite labor / return‑shipment freight included.
7. Bulk‑order support: For compressor‑service contractors, pre‑shipment inspection, heavy‑duty export fumigated wooden crate for sea‑freight transit.
8. Technical backup: Installation checklist and troubleshooting reference for on‑site technicians.
Compatibility & Pre‑Order Verification Checklist
OEM Part Number:5.7616E3
Product Type:2‑in‑one integrated Combi‑Cooler (Oil cooler + Compressed‑air aftercooler)
Material:High‑grade aluminum bar‑plate core, painted steel mounting frame
Applicable Compressor:Matched stationary Kaeser ASD / BSD / CSD oil‑injected rotary screw compressor
Information we require before quotation:
1. Full compressor serial‑number from machine name‑plate
2. Clear photo of old combi‑cooler name‑plate marking
3. Fault symptom description (high‑temp shutdown / external leakage / suspected cross‑circuit leak)
4. Working‑site environment: indoor / heavy‑dust / high‑ambient‑temperature
5. Order requirement: single emergency spare / bulk project stock
Replacement decision reference
‑ Recommend 5.7616E3 full combi‑cooler swap‑out: internal core leakage, internal channel irreversible fouling, core physical crack.
‑ Do not replace combi‑cooler blindly: when fault comes from clogged external fins, defective fan motor, failed thermostatic element or degraded compressor lubricant.
Core Functional Benefits
1. Dual‑circuit integrated cooling performance for Kaeser ASD‑BSD‑CSD unit
One single aluminum bar‑plate assembly fulfills both lubricant oil cooling and compressed‑air post‑cooling function. Restores original design heat‑exchange capacity for aging Kaeser screw compressor. Stabilize oil temperature to protect air‑end bearing & rotor profile; reduce compressed‑air outlet temperature to lower burden for downstream air‑dryer and inline filters.
2. Bar‑plate aluminum core resisting typical compressor working cycle
Industrial‑grade aluminum bar‑plate construction tolerates normal pressure fluctuation and temperature cycling inside Kaeser combi‑cooler system. Suitable for continuous‑running production‑critical compressed‑air stations.
3. Matched port & mounting footprint for drop‑in replacement
Port layout, oil‑circuit connection and mounting frame dimension match OEM combi‑cooler assembly. No large‑scale frame modification required for swap‑out. Mandatory preparatory work: drain full lubricant oil and replace complete set of sealing gaskets.
4. Avoid cross‑circuit oil‑air leakage risk with new gaskets
This combi‑cooler separates oil loop and compressed‑air loop. Aged, degraded gaskets will create cross‑leak path: lubricant oil flows into compressed‑air side and causes severe oil‑carry‑over issue. Always install brand‑new full gasket set together with new cooler assembly.
5. Reduce downstream maintenance cost
Qualified combi‑cooler lowers compressed‑air outlet temperature, reduces condensed water load for dryer system, extends service‑life of downstream inline filter consumables.
Technical Specification
| Parameter | Value |
|---|---|
| Part Number | 5.7616E3 |
| Assembly Type | Integrated 2‑in‑one Combi‑Cooler (Oil cooler + Compressed‑air aftercooler) |
| Core Construction | Aluminum bar‑plate heat‑exchange core, painted steel mounting frame |
| Working medium 1 | Compressor circulating lubricant oil |
| Working medium 2 | Hot compressed air from air‑end |
| Max design working pressure | 13 bar |
| Working ambient temperature | ‑10℃ ~ +45℃ |
| Installation | Cabinet frame mounting for stationary screw compressor |
| MOQ | 1 Piece |
| Shipment Option | DHL/FedEx/UPS express, air freight, sea‑freight with export fumigated wooden crate |
| Payment Terms | T/T, PayPal, Western Union |
| Important Remark | Not plug‑and‑play; drain full oil, replace complete gaskets, vent air‑pockets, full‑load temperature observation required |
Good Customers Reviews

Risk of Low‑Grade Aftermarket Combi‑Cooler
Selecting combi‑cooler purely based on low purchase price brings significant hidden risk for your Kaeser compressor asset:
1. Poor‑quality aluminum core heat‑exchange efficiency: Insufficient cooling capacity, compressor keeps triggering high‑temperature alarm even after replacement.
2. Internal channel dimension mismatch: Improper flow resistance leads to abnormal oil pressure or excessive compressed‑air pressure‑drop.
3. Poor welding workmanship: Hidden micro‑leaks, risk of oil‑air cross‑circuit contamination after short runtime.
4. Incorrect port / mounting dimension: Requires on‑site modification, increases installation labor cost and downtime.
Cost insight: Combi‑cooler is high‑value core thermal component. Cheap inferior replacement will cause repeated over‑temperature trip‑out, downstream dryer / filter damage, and production loss. Saving small upfront part cost may result in multiple‑fold indirect losses.
Typical Application Scenarios
This 5.7616E3 combi‑cooler serves industrial facilities running matched stationary Kaeser ASD‑BSD‑CSD screw compressors:
‑ General manufacturing & metal‑working workshops
‑ Automotive assembly & painting facilities
‑ Plastic‑processing production‑lines
‑ 24‑hour continuous‑run light‑industry compressed‑air stations
‑ Compressor service & rental companies for maintenance spare‑parts stocking
Evaluate combi‑cooler replacement project when you observe: persistent high‑temperature shutdown, visible external coolant leakage, confirmed internal core leakage or irreversible heavy internal fouling. Always complete peripheral component troubleshooting before ordering new combi‑cooler.
Critical On‑Site Installation & Post‑Replacement Guidance
Safety Warning: Strictly perform full LOTO lock‑out‑tag‑out procedure. Shut‑down compressor completely, release all system pressure; wait for full cooling before opening oil‑circuit connections. Hot lubricant can cause severe scald injury.
1. Pre‑installation system preparation (Most‑skipped critical step)
Power‑off, depressurize and fully cool compressor. Drain out all old compressor lubricant oil completely from oil separator tank and combi‑cooler loop. Disconnect oil‑circuit piping and compressed‑air port connections. Remove old combi‑cooler assembly. Clean residual sludge on mounting frame.
Mandatory step: Discard all aged gaskets. Prepare brand‑new full set of matching sealing gaskets for oil‑circuit and air‑circuit interfaces. Never reuse old gaskets.
2. New combi‑cooler mounting and piping connection
Install brand‑new 5.7616E3 combi‑cooler onto mounting frame. Fit all new gaskets. Re‑connect oil‑circuit and compressed‑air ports. Follow service‑manual torque specification for each fitting; avoid over‑torque which cracks aluminum thread / flange.
3. System filling and air‑pocket venting
Refill qualified Kaeser‑spec compressor lubricant oil into system. Perform careful venting to remove trapped air‑pockets inside oil‑cooling loop. Air pockets inside heat‑exchanger will cause insufficient cooling and false high‑temperature alarm after startup.
4. Post‑start‑up full‑load commissioning and baseline recording
Restore power supply. Run compressor under stable full‑load condition minimum 60‑90 minutes:
‑ Continuously monitor compressor lubricant oil operating temperature;
‑ Measure compressed‑air outlet temperature and observe condensate‑drain performance;
‑ Inspect all port joints for oil or air leakage;
‑ Record baseline temperature reading for future maintenance reference.
5. Troubleshooting hint after replacement If compressor still reports high‑temperature alarm after fitting brand‑new 5.7616E3 combi‑cooler: Do NOT judge cooler defective directly. Re‑check: air‑pocket venting status, cooling fan performance, thermostatic element condition, lubricant oil quality and external fin cleanliness.
Spare‑Part Planning & Bulk‑Procurement Guidance
For factory‑maintenance‑teams and compressor‑service‑contractors:
1. Emergency single‑unit order: Fast air‑express shipment for sudden breakdown to minimize production downtime.
2. Quarterly / annual bulk‑procurement: Planned maintenance project, better unit‑price and predictable lead‑time.
3. Combined‑consumable‑kit: Bundle combi‑cooler with matched oil filter, oil‑separator and thermostatic element for complete overhaul project.
4. Reserved‑stock program: We can reserve inventory for regular‑customers against global spare‑part supply fluctuation.
5. Pre‑shipment inspection: Visual check core welding integrity, port dimension and mounting frame; bulk‑order inspection photos available upon request. Heavy‑duty export fumigated wooden crate for sea‑freight transit.
Inventory suggestion: Keep spare‑part lead‑time documented in your maintenance plan for critical 24‑h running Kaeser ASD‑BSD‑CSD compressors. Combi‑cooler is large‑size long‑lead‑time spare‑part; unexpected failure may cause extended production halt.
Frequently Asked Questions
Q1: Compressor triggers high‑temperature shutdown, must I replace 5.7616E3 combi‑cooler?
A: Not necessarily. Complete troubleshooting checklist first: clean clogged cooler fins, check cooling fan motor, inspect thermostatic element and lubricant quality. A large percentage of high‑temperature alarms root in peripheral components instead of defective combi‑cooler core.
Q2: Is 5.7616E3 combi‑cooler plug‑and‑play after bolting onto frame?
A: No, it is not plug‑and‑play. You need full oil draining, gasket renewal, trapped air‑pocket venting, and long‑period full‑load temperature validation. Mechanical fitting alone cannot guarantee normal cooling performance.
Q3: What risk if I reuse old gaskets for combi‑cooler replacement?
A: Aged gaskets lose elasticity. It may create cross‑circuit leakage path: compressor lubricant oil leaks into compressed‑air side, resulting in severe oil‑carry‑over contaminating production pipeline and downstream air treatment equipment. Always fit complete new gasket set.
Q4: Does 5.7616E3 fit every Kaeser ASD‑BSD‑CSD compressor?
A: No. Even similar outer dimension, internal flow‑channel and port specification may differ per machine hardware revision. Submit full compressor serial‑number for compatibility cross‑check before ordering.
Q5: After new combi‑cooler installation compressor still overheats, what are common causes?
A: Common root‑causes: incomplete venting of air‑pockets inside oil‑loop; defective cooling fan; failed thermostatic element; degraded lubricant oil; external cooler fins covered with dust debris.
Q6: What damage situation is excluded under limited product warranty?
A: Limited warranty only covers manufacturing‑related defects of combi‑cooler assembly. Excluded: internal fouling / contamination damage, mechanical shock / over‑torque installation damage; onsite labor and return‑shipment freight are not included.
Request Technical Quotation for 5.7616E3 Combi‑Cooler Assembly
Fill inquiry‑form with compressor serial‑number, fault description, quantity and destination‑country. Our sales‑engineer will reply quotation, technical notes and lead‑time promptly.
Hot Tags: 5.7616E3 Combi Cooler | Kaeser ASD‑BSD‑CSD Screw Compressor, China 5.7616E3 Combi Cooler | Kaeser ASD‑BSD‑CSD Screw Compressor manufacturers, suppliers, Oil Cooler for Kaeser Compressor, 5 7626 0, Cooler replacement for kaeser, Kaeser Cooler Replacement, 5 7602 3, Replacement Kaeser Oil Cooler