Product Overview
Part number 02250071‑151 is aftermarket replacement controller for Sullair V‑Plus (Versatility) control platform, designed for LS series stationary rotary screw air compressors. It acts as central control unit to manage compressor loading‑unloading logic, safety interlock shutdown, runtime logging, alarm & diagnostic functions.
Critical technical clarification: This is aftermarket replacement unit, NOT genuine OEM original part. Important compatibility note: Even with identical part‑number 02250071‑151, there exist different hardware revisions and firmware variants. This controller is NOT true plug‑and‑play. After mechanical installation, complete parameter configuration is mandatory according to the actual compressor hardware configuration. Site technician shall have access to V‑Plus service‑level password for setup.
ESD safety reminder: This is sensitive electronic PCB assembly. Electro‑Static‑Discharge (ESD) may cause invisible permanent circuit damage during handling. Anti‑static wrist strap and anti‑static working environment are required during installation and service.
Field‑service troubleshooting note: If compressor still triggers fault alarms after installing brand‑new 02250071‑151 controller, do not directly judge new controller defective. Perform inspection workflow: check sensor signal, transducer wiring, current transformer, power‑supply quality and peripheral interlock hardware before concluding controller hardware failure.
Critical buying alert: Part‑number "02250071‑151" alone cannot guarantee perfect compatibility with your machine. Please submit below information for our pre‑order technical cross‑verification: full Sullair compressor serial‑number, clear photo of old controller name‑plate label, original firmware revision, compressor motor power rating. Avoid wrong‑part delivery and costly on‑site downtime.
Supply scope notice: We supply controller hardware unit only. Remote or on‑site commissioning / parameter programming service is NOT included in this offer. Customer shall arrange local qualified technician familiar with Sullair V‑Plus platform for configuration work.
Customer Buying & Maintenance Priorities
Industrial maintenance buyers sourcing Sullair replacement controller consider multi‑dimensional practical concerns beyond unit price:
1. Compatibility‑check risk: Same part‑number may carry different hardware / firmware revisions; compressor serial‑number plus old‑controller label photo are required for pre‑order validation.
2. Replacement workflow awareness: Not plug‑and‑play; full parameter re‑configuration required after installation; service‑level menu password access is necessary.
3. ESD operation risk: Sensitive electronic board; static discharge will cause invisible permanent PCB damage.
4. Fault‑diagnosis workflow: Persistent alarms after controller swap do not always mean bad controller; inspect sensors, wiring and peripheral components first.
5. Service‑scope awareness: Only controller hardware is delivered; commissioning & programming work needs local on‑site technician.
6. Warranty‑scope clarity: Limited‑warranty only covers manufacturing‑related hardware defects. Exclude damage caused by ESD static, mis‑wiring, over‑voltage surge, incorrect parameter configuration; onsite / remote commissioning labor not covered.
7. Project‑order support: For compressor service contractors; anti‑static shock‑proof export packing; pre‑shipment power‑on test photos available upon request.
8. Technical‑backup: Provide installation & replacement reference checklist for on‑site technician reference.
Compatibility & Pre‑Order Verification Checklist
Reference OEM Part‑No:02250071‑151
Product Type:Aftermarket Replacement V‑Plus (Versatility) Compressor Controller / HMI‑PCB Assembly
Reference applicable machine:Sullair LS‑10, LS‑12, LS‑16, LS‑20 stationary rotary screw compressors
Information we require before quotation:
1. Full Sullair compressor serial‑number from machine nameplate
2. Clear photo of old controller back‑side label (show part‑no, hardware revision & firmware version)
3. Compressor motor power rating
4. Working‑site environment: Control cabinet power‑supply stability; risk of voltage surge
5. Order‑type: Single emergency spare‑part / bulk stock‑up for service fleet
Order‑decision reference
‑ Suitable: Your existing unit is V‑Plus platform, machine belongs to LS‑10 / LS‑12 / LS‑16 / LS‑20 series, local technician has V‑Plus configuration capability.
‑ Need further re‑evaluation: Machine uses different Sullair control platform (Compass / STS); no local technician familiar with V‑Plus parameter programming; frequent power‑grid surge on‑site.
Core Functional Benefits
1. Full V‑Plus platform function matching
Replicates core control logic of original V‑Plus controller: load‑unload modulation control, multi‑level safety shutdown protection, real‑time fault diagnostic logging, maintenance hour counter, pressure‑setpoint adjustment menu. Supports local on‑machine operation for LS‑series screw compressors.
2. Integrated fault diagnostic system
Multi‑grade warning & shutdown alarm classification. Technicians can read fault history log for fast failure localization, shorten troubleshooting time during compressor breakdown repair.
3. User‑friendly menu HMI interface
Structured menu navigation for pressure set‑points, maintenance timers, runtime statistics and system parameter groups. Password‑protected service menu for machine‑specific configuration.
4. Industrial anti‑interference hardware design
Designed to adapt compressor cabinet environment with electric noise, temperature fluctuation. Suitable for typical industrial compressor‑room conditions.
5. Communication expansion capability
Reserved RS485 / RS232 interface; Modbus function available with optional add‑on communication card for remote monitoring system integration.
Technical Specification
| Parameter | Value |
|---|---|
| Reference Part Number | 02250071‑151 |
| Controller Platform | V‑Plus (Versatility) |
| Product Type | Aftermarket replacement HMI & main PCB controller assembly |
| Nominal Input Power | 24 V DC (supplied by compressor internal control transformer) |
| Communication Interface | RS485 / RS232 (Modbus via optional add‑on card) |
| Reference Applicable Units | Sullair LS‑10, LS‑12, LS‑16, LS‑20 rotary screw compressors |
| Important Remark | Aftermarket replacement (non‑OEM original); NOT plug‑and‑play; parameter configuration required after installation; ESD‑sensitive electronic component |
| MOQ | 1 Unit |
| Shipment Option | Sea‑freight with anti‑static shock‑proof export packing, air‑freight |
| Payment Terms | T/T, PayPal, Western Union |
| Important Warranty Note | ESD damage, wrong wiring, over‑voltage, wrong configuration excluded from product warranty; commissioning service not included |
Good Customers Reviews

Risk Of Mis‑Application & Wrong‑Selection
Ordering controller purely based on part‑number 02250071‑151 creates serious hidden operational risk:
1. Ignore hardware / firmware revision difference: Same part‑number may contain different hardware‑firmware variants, cause IO mismatch, function abnormality if skip compatibility cross‑check.
2. Mis‑understand as plug‑and‑play replacement: Expect unit runs automatically after wiring without parameter setup; compressor cannot start or triggers continuous safety‑shutdown.
3. Neglect ESD protection: Static electricity during installation brings invisible permanent PCB damage; this kind of damage cannot be identified visually and is excluded from warranty.
4. No local V‑Plus‑qualified technician available: Hardware delivered, but no‑one can complete machine‑specific parameter configuration, spare‑part cannot be put into service.
5. Misjudge new‑controller fault: After replacement compressor still alarms, skip peripheral‑check and directly return controller, wasting logistics & production downtime.
Cost insight: Electronic controller is high‑value sensitive spare‑part. Compatibility validation, anti‑static handling and correct post‑installation configuration are equally important as hardware quality. Improper operation may lead to expensive compressor stand‑still loss.
Typical Application Scenarios
This 02250071‑151 aftermarket V‑Plus replacement controller is used for repair & spare‑part replacement of matched Sullair LS‑series screw compressors originally equipped with V‑Plus(Versatility) control system:
‑ Factory‑site compressor breakdown emergency repair
‑ Compressor service & rental fleet spare‑parts stocking
‑ General manufacturing plant compressed‑air station maintenance
Reminder: Not compatible with Sullair Compass, STS‑Touch‑Screen or other different control platforms. This hardware does not include on‑site or remote programming / commissioning service.
Critical On‑Site Installation & Replacement Guidance
Safety & ESD Warning:
1. Perform full LOTO lock‑out‑tag‑out procedure. Disconnect complete main power supply and confirm zero‑voltage before opening control cabinet.
2. This is ESD‑sensitive electronic assembly. Wear anti‑static wrist‑strap connected to reliable earth‑ground during whole handling procedure. Static discharge can destroy circuit board without visible traces.
1. Pre‑replacement preparation
Before removing old faulty controller: Record all critical operating parameters from display (load / unload pressure, maintenance timer values). Take clear photos for every wiring connector, ribbon‑cable position for reference during re‑assembly. Collect old‑controller label information for future traceability.
2. Remove existing controller unit
Carefully unplug ribbon cables and terminal connector blocks. Unscrew mounting fasteners, take out old controller assembly from cabinet door / back‑plate. Avoid pulling hard on wiring harness.
3. Mount new 02250071‑151 controller
Fix new controller onto original mounting position. Re‑install all ribbon cables and terminal connectors, ensure each connector is fully seated and locked. Complete reliable protective earth‑ground connection.
4. Power‑on & parameter configuration (mandatory step)
Restore cabinet power‑supply. Controller will run self‑test after power‑on. Enter service‑level password‑protected menu, input compressor‑specific parameters: motor rating, pressure thresholds, protection thresholds, date‑time and hardware‑relevant settings according to actual machine configuration.
※Do NOT skip parameter configuration step. Unit will not operate correctly without correct machine‑specific setup.
5. Post‑commissioning functional verification
Run compressor under test condition. Observe loading‑unload cycle behaviour, check real‑time temperature & pressure reading, inspect active fault‑alarm list. Simulate normal start‑stop cycle to confirm full control‑logic works as expected.
6. Troubleshooting hint after replacement
If compressor keeps reporting fault codes after installing new controller: Do NOT judge new controller defective directly. Re‑inspect wiring connections, transducer / sensor health condition, current transformer and power‑supply quality. Many fault events root in peripheral components instead of controller hardware itself.
Spare‑Part Planning Guidance
For factory‑maintenance‑teams and compressor‑service‑contractors:
1. Single emergency spare‑part: Air‑express shipment for on‑site breakdown repair.
2. Service‑fleet bulk‑stock‑up: Anti‑static shock‑proof export packing; pre‑shipment power‑on test photos can be provided upon request.
3. Important note: Please arrange local on‑site technician familiar with Sullair V‑Plus system for parameter configuration after hardware arrival. We do not supply remote programming service.
Inventory suggestion: Keep critical controller spare on‑site for 24‑h continuous‑production Sullair LS‑series compressors, and ensure site has qualified V‑Plus‑capable technician resource.
Frequently Asked Questions
Q1: Is 02250071‑151 plug‑and‑play, can I run directly after wiring?
A: No. It is NOT plug‑and‑play. After mechanical installation you must enter service‑password menu and complete compressor‑specific parameter configuration according to actual machine hardware. Local experienced technician is required.
Q2: Why do you need compressor serial‑number and old‑controller photo for order confirmation?
A: Even with same part‑number 02250071‑151, there are different hardware‑revision and firmware variants. We perform cross‑check to avoid compatibility mismatch risk.
Q3: My compressor still shows alarm codes after installing new 02250071‑151 controller, is controller defective?
A: Not necessarily. Please check wiring harness, sensors, transducers, current transformer and cabinet power‑supply first. A large share of faults are caused by peripheral components, not controller hardware.
Q4: Does product include remote or on‑site parameter programming / commissioning service?
A: No. Only controller hardware is supplied. Customer shall arrange local technician who is familiar with Sullair V‑Plus control platform for configuration work.
Q5: What situation will void the limited product warranty for this electronic controller?
A: Warranty only covers manufacturing hardware defects. Damage caused by ESD static discharge, mis‑wiring, power‑supply over‑voltage surge, incorrect parameter configuration are excluded. On‑site labor cost is not covered.
Q6: Which compressor series does 02250071‑151 fit?
A: Reference for Sullair LS‑10, LS‑12, LS‑16, LS‑20 stationary screw compressors with original V‑Plus (Versatility) control system. Not compatible with Compass / STS and other different control platforms.
Request Technical Quotation for 02250071‑151 V‑Plus Replacement Controller
Fill inquiry‑form with compressor serial‑number, old‑controller information, motor power, quantity and destination‑country. Our sales‑engineer will reply quotation and lead‑time promptly.
Hot Tags: 02250071‑151 V‑Plus Controller For Sullair Screw Compressor, China 02250071‑151 V‑Plus Controller For Sullair Screw Compressor manufacturers, suppliers, Sullair Replacement Controller panel 88290007 789, sullair controller panel 88290021 398, 88290014-903, 88290007-999, sullair controller panel 88298002 312, Sullair Air Compressor Electric Controller Panel