Details:
Product Number: JRZ-YDXGL-25
Product Type: Heated Air Dryer for Compressed Air System
Working Pressure:7bar
Exhaust volume:25 m3/min
Motor Power:12KW
Cooling Method:Water Cooled
Payment terms: Paypal, T/T, Western Union, Visa
MOQ: 1Pcs
Customization service: Support customization
Shipping method: Sea/Air
Send Inquiry
Description
Send Inquiry
Tips: Due to the wide variety of air dryer, it may not be possible to display them all on the website. If you need any, please contact us by email or phone.
 

Product Overview

 

This 25 m³/min water‑cooled blower‑purge heated regenerative desiccant dryer is twin‑tower adsorption equipment for industrial compressed‑air treatment. It applies pressure‑swing‑adsorption principle: one tower adsorbs water‑vapor from incoming compressed‑air; meanwhile the second tower runs regeneration cycle. Different from heat‑less type which consumes large volume of dried process‑air for regeneration, this blower‑purge design uses separate ambient‑air blower plus electric heater to heat regeneration air. It minimizes consumption of valuable finished compressed‑air, lowering overall system operating‑cost for continuous‑run production facilities.

 

Critical specification note: 25 m³/min is nominal flow‑rate under standardized reference working‑conditions. Real‑world effective drying capacity will decrease if inlet compressed‑air temperature, working pressure, cooling‑water inlet temperature or ambient environment deviate from design parameters. Purely selecting unit by nominal flow without reviewing site‑conditions may result in failure to meet target pressure dew‑point on‑site.

 

Very important field‑service reminder: Rising outlet dew‑point or increased system pressure‑loss do not automatically mean dryer hardware defect. Common root‑causes come from upstream system rather than dryer itself: pre‑filter element saturated / oil contamination, insufficient or over‑heated cooling‑water, clogged blower intake filter, faulty temperature sensor or blocked exhaust muffler. Complete upstream troubleshooting before judging dryer failure.

 

Media lifetime reality: Desiccant beads are consumable wearing parts. Oil aerosol carry‑over coming from upstream compressor will permanently poison desiccant adsorption pores. Once poisoned, desiccant cannot recover performance by regeneration cycle, and requires full replacement. Good pre‑filtration system is the decisive factor for desiccant service‑life.

 

Configuration note: Standard unit is built for general‑purpose industrial compressed‑air treatment. Food‑processing HACCP, pharmaceutical GMP compliance are NOT included in base configuration. Stainless‑steel wetted parts, upgraded filtration and special internal surface treatment are required as optional add‑on packages for hygiene‑critical production lines.

 

Critical buying alert: Nominal model specification alone cannot confirm real‑world matching performance. Please provide full site operating‑condition information for our technical cross‑verification before quotation, to avoid on‑site capacity mismatch and costly production‑downtime.

 

Customer Buying & Maintenance Priorities

 

Industrial buyers evaluating blower‑purge heated desiccant dryer consider multi‑dimensional practical concerns beyond unit price. Below key practical concerns are fully addressed on this page:

1. Capacity‑selection risk: Nominal 25 m³/min rating is for reference‑conditions only; site inlet‑air, cooling‑water parameters change real usable capacity. Submit site‑data for pre‑order validation.

2. Fault‑diagnosis workflow: Avoid direct dryer‑hardware condemnation; inspect upstream pre‑filters, cooling‑water, blower intake filter and sensors when facing high dew‑point alarm.

3. Consumable awareness: Desiccant beads are wearing consumables; upstream oil‑carry‑over causes permanent desiccant poisoning. Pre‑filtration system determines media lifespan.

4. Installation‑operation risk awareness: Water‑cooled version relies on stable cooling‑water supply; blower intake must keep free of dust‑blockage.

5. Desiccant refill rule: Never over‑compact desiccant beads during refilling; over‑compaction accelerates bead crushing and generates large amount of fine dust.

6. Special‑application awareness: HACCP / GMP food‑pharma requirements are optional upgrade packages, not standard delivery scope.

7. Warranty‑scope clarity: Warranty only covers dryer hardware manufacturing‑defects. Excluded: desiccant wear/poisoning, improper cooling‑water supply, site‑conditions deviate from design; onsite commissioning labor and return‑shipment freight not covered.

8. Bulk‑order & project support: For system integrators & compressor‑service contractors, we accept project‑based inquiry; provide technical drawing, reference operating‑checklist, export‑grade heavy‑duty packing.

 

Compatibility & Pre‑Order Site‑Condition Checklist

 

Product Type:Water‑Cooled Blower‑Purge Heated Regenerative Desiccant Compressed‑Air Dryer

Nominal Rated Flow:25 m³/min (under standard reference conditions)

Rated Working Pressure:7 bar

Heater Rated Power:12 kW

Cooling Method:Water‑Cooled

Power Supply:380 V / 50 Hz 3‑Phase

 

Information we require before quotation (please fill site‑condition details):

1. Actual working pressure range on‑site

2. Real‑inlet compressed‑air temperature

3. Cooling‑water inlet temperature & available water flow

4. Average / peak compressed‑air consumption

5. Target required pressure dew‑point

6. Up‑stream equipment condition: compressor type, existing pre‑filter configuration

7. Application: general‑industry / food‑pharma hygiene‑critical (if yes, specify hygiene‑requirements)

8. Order type: single‑unit replacement / system‑integration project / bulk‑stock

 

Order‑decision reference

‑ Select this model: Site‑conditions match reference‑spec; demand 25 m³/min treated compressed‑air, water‑cooling resource available.

‑ Need further re‑calculation: High inlet‑air temperature, poor cooling‑water condition, hygiene‑critical production, large peak‑flow fluctuation.

 

Core Functional Benefits

 

1. Blower‑purge regeneration reduces finished compressed‑air waste

Adopts independent blower‑heated ambient‑air regeneration principle. It avoids high‑volume consumption of valuable dried process‑compressed‑air compared with traditional heat‑less desiccant dryers, lowering continuous‑run plant air‑system energy loss.

2. Twin‑tower alternating adsorption‑regeneration cycle

One tower keeps continuous compressed‑air drying service while opposite tower completes full heating & cooling regeneration procedure. Achieves uninterrupted supply of dry compressed‑air for plant pneumatic equipment.

3. Water‑cooled heat‑dissipation for stable performance under high‑ambient‑temperature workshop

Water‑cooled design removes regeneration‑cycle excess heat effectively. Maintains stable internal thermal balance for sites with high‑ambient‑temperature, where air‑cooled dryers may suffer performance drift.

4. PLC‑based automatic cycle‑control

Automatic tower‑switching, heater logic and regeneration‑sequence control. Supports standard time‑based cyclic operation; optional dew‑point‑driven energy‑saving switching function available as add‑on. Local HMI status display for alarm, cycle status and fault hint.

5. Structural design considering real‑world maintainability

Human‑oriented access for routine service: blower intake filter replacement, desiccant filling‑port, drain points, sensor inspection ports. Exhaust muffler is serviceable component for capturing desiccant fines generated over service‑time.

 

※Important note: Desiccant beads, blower intake filter and exhaust muffler elements belong to wearing consumables, not covered by main‑unit hardware warranty.

 

Technical Specification

 

Parameter Value
Nominal Flow Rate 25 m³/min (standard reference‑conditions only)
Working Pressure 7 bar (custom pressure range available upon request)
Heater Power 12 kW
Power Supply 380 V‑50 Hz 3‑Phase
Cooling Mode Water‑Cooled
Dimension (LWH) 1830 * 1090 * 2145 mm
Control System PLC automatic cyclic control, local HMI status & alarm display
Regeneration Method Blower‑purge externally‑heated regeneration
Consumables Desiccant beads, blower intake filter, exhaust muffler insert
MOQ 1 Unit
Shipment Option DHL/FedEx/UPS air‑express, sea‑freight with export fumigated wooden crate
Payment Terms T/T, PayPal, Western Union
Important Remark Nominal flow depends on real‑site inlet‑air & cooling‑water conditions; desiccant is consumable; HACCP/GMP is optional upgrade package

 

Good Customer Reviews

 

product-805-764               product-670-647                product-685-632

 

Risk Of Mis‑application & Low‑Grade Substitute Dryer

 

Selecting blower‑purge desiccant dryer purely on nominal flow‑rate and low‑purchase‑price creates hidden operational risks for your compressed‑air system:

1. Ignoring real‑site boundary‑conditions: Buying according to 25 m³/min nominal‑value only. Once inlet‑air temperature or cooling‑water deviates, actual drying capacity drops, dew‑point fails to reach target.

2. Poor‑quality desiccant media: Low‑grade beads crush easily under cyclic pressure swing; generating massive dust contaminating downstream filters and pneumatic actuators, increasing whole‑system maintenance workload.

3. Unreliable heater‑control & temperature‑sensing circuit: Incorrect regeneration‑temperature leads to incomplete moisture desorption; desiccant performance degrades rapidly in short runtime.

4. Weak blower assembly: Under‑sized or low‑quality regeneration‑blower cannot deliver sufficient regeneration‑air volume, causing unstable tower‑regeneration and drifting outlet dew‑point.

 

Cost insight: Up‑front saving on cheap dryer unit can bring repeated production‑quality trouble, frequent consumable replacement and production‑line downtime. Desiccant dryer is critical core link for compressed‑air‑quality guarantee.

 

Typical Application Scenarios

 

This 25 m³/min water‑cooled blower‑purge heated desiccant dryer serves industrial‑facilities requiring stable low‑dew‑point compressed‑air:

‑ General‑manufacturing & metal‑processing workshops

‑ Automotive assembly, paint‑spray production‑lines

‑ Plastic‑injection & extrusion factories

‑ 24‑hour continuous‑run industrial compressed‑air‑stations

‑ Compressed‑air system integrators and compressor‑service contractors

 

Evaluate this dryer unit when you require dew‑point performance beyond refrigerated dryer capability, and water‑cooling resource is available on‑site.

 

Reminder: For food‑pharmaceutical hygiene‑critical process, please request optional upgrade‑package; base unit is for general‑industry purpose only.

 

Critical On‑Site Installation, Commissioning & Maintenance Guidance

 

Safety Warning: Strictly perform full LOTO lock‑out‑tag‑out procedure. Cut off main‑power, release internal system pressure before opening access‑ports for any maintenance‑work. High‑temperature heater‑components present burn hazard.

1. Pre‑installation site preparation

Confirm stable qualified cooling‑water supply with correct flow‑rate and inlet‑temperature. Complete upstream compressed‑air pipeline layout; install matched pre‑filter / coalescing‑filter set ahead of dryer inlet to trap oil‑aerosol and solid particles. Poor pre‑filtration will lead to fast desiccant poisoning failure. Level‑mount dryer on solid foundation.

2. Piping & electrical connection work

Connect compressed‑air inlet / outlet pipeline, cooling‑water in‑out circuit, drain‑lines. Complete 3‑phase power‑wiring strictly follow name‑plate specification. Keep blower intake ventilation opening unobstructed, no dust accumulation surroundings.

3. Startup & commissioning procedure

Power‑on unit; run full automatic multi‑cycle test. Monitor tower‑switch action, heater working status, blower running sound, cooling‑water flow condition. Log outlet dew‑point trend for several full adsorption‑regeneration cycles to verify real‑performance. Check exhaust muffler for abnormal desiccant‑dust discharge sign.

4. Routine periodic‑maintenance key points

‑ Check blower intake filter regularly; replace once clogged; blocked intake reduces regeneration‑air volume directly.

‑ Inspect exhaust muffler element: if large‑amount desiccant‑fines collected, investigate bead‑crushing root‑cause.

‑ Monitor outlet dew‑point trend as long‑term reference index.

‑ When refilling desiccant beads: fill evenly, DO NOT over‑compact or hammer beads. Over‑compaction accelerates bead crushing and dust‑generation.

5. Troubleshooting hint after commissioning

If outlet dew‑point rises obviously:

Do NOT judge dryer defective directly. Re‑check upstream pre‑filter condition, cooling‑water supply status, blower intake filter blockage, heater‑temperature‑sensor reading, exhaust‑muffler fouling. Most dew‑point‑drift issues root in peripheral system instead of dryer main‑body.

 

Spare‑Part Planning & Bulk‑Procurement Guidance

 

For factory‑maintenance‑teams, compressed‑air‑system integrators and compressor‑service‑contractors:

 

1. Emergency single‑unit order: Sea‑/air‑freight delivery for system‑renewal or breakdown‑replacement.

2. Quarterly / annual project‑bulk‑procurement: For multi‑plant system‑integration projects; better unit‑price and stable lead‑time.

3. Consumable‑kit combined‑order: Bundle with desiccant beads, blower intake filter, muffler‑insert consumables for one‑stop spare‑part procurement.

4. Reserved‑stock‑program: We can reserve inventory for regular‑customers against global supply‑chain fluctuation.

5. Pre‑shipment inspection: Functional run‑test before packing for project orders; inspection photos available upon request. Heavy‑duty export fumigated wooden‑crate for sea‑freight long‑distance transit.

 

Inventory suggestion: Keep critical consumables (blower intake‑filter, spare muffler‑insert) in‑stock for 24‑h continuous‑production site. Desiccant beads shall be planned as periodic‑replacement wearing media.

 

Frequently Asked Questions

 

Q1: The model is 25 m³/min, can it handle 25 m³/min all‑the‑time under any site‑condition?

A: No. 25 m³/min is nominal flow‑rate under standardized reference‑conditions. Higher inlet‑compressed‑air temperature, insufficient / hot cooling‑water will reduce real drying capacity. Please provide on‑site operating‑data for capacity evaluation before order.

Q2: My dryer outlet dew‑point becomes higher, must the dryer hardware be broken?

A: Not necessarily. Please check upstream pre‑filter oil‑contamination, cooling‑water supply, blower intake filter blockage, heater and temperature‑sensor status, exhaust muffler fouling first. Many dew‑point‑drift faults are caused by peripheral system components.

Q3: Can this base‑model dryer directly be used for food‑processing / pharmaceutical GMP production‑lines?

A: No. Base‑version is for general‑industrial compressed‑air. Food‑pharma hygiene requirements require optional upgrade package (stainless‑steel wetted‑parts, upgraded‑filter set and special internal‑surface‑treatment). Please mention hygiene‑requirement in inquiry.

Q4: Can I hammer / compact desiccant beads very tight when refilling?

A: Strictly avoid over‑compacting or hammering desiccant beads. Over‑compression causes bead crushing under cyclic pressure‑swing, generating large‑volume fine‑dust contaminating downstream equipment. Fill evenly only.

Q5: Why desiccant beads fail in a short period even dryer runs normally?

A: Most frequent root‑cause is oil‑aerosol carry‑over from upstream compressor. Oil contaminant permanently poisons desiccant adsorption pores, and cannot be recovered by regeneration cycles. Up‑stream coalescing pre‑filter is essential protection. Desiccant belongs to wearing consumable part.

Q6: What damage situation is excluded under limited product warranty?

A: Limited‑product‑warranty only covers dryer main‑unit hardware manufacturing‑defects. Excluded: desiccant‑bead wear & poisoning, improper cooling‑water supply, site‑conditions deviate from design‑spec; onsite commissioning labor and return‑shipment freight are not included.

 

Request Technical Quotation for 25 m³/min Blower‑Purge Heated Regenerative Desiccant Dryer

Fill inquiry‑form with full‑site operating‑conditions, special‑requirements, quantity and destination‑country. Our sales‑engineer will reply quotation and lead‑time promptly.

Hot Tags: 25 m³/min Blower‑Purge Heated Desiccant Air Dryer | Compressed‑Air, China 25 m³/min Blower‑Purge Heated Desiccant Air Dryer | Compressed‑Air manufacturers, suppliers

Send Inquiry