Tips: Due to the wide variety of air compressors, it may not be possible to display them all on the website. If you need any, please contact us by email or phone.
Product Overview
Part number JRZ‑150AZ/0.8 is oil‑injected single‑stage fixed‑speed (power‑frequency) belt‑drive rotary screw air compressor, rated motor power 110 kW, nominal free‑air delivery 19.8 m³/min at 0.8 MPa working pressure, air‑cooled design. It is built for industrial sites with relatively stable continuous compressed‑air consumption.
Critical technical clarification: This is oil‑injected screw compressor unit. It cannot produce ISO 8573‑1 Class0 oil‑free compressed‑air. If you require high‑purity compressed‑air for laser‑cutting or precision‑process, you need to configure separate downstream refrigerated dryer + multi‑stage inline filter set after compressor outlet.
Belt‑drive specific note: Power transmits from motor to air‑end via industrial V‑belt set. Belt slipping, improper tension or aging wear will directly reduce real‑world air output and trigger abnormal over‑heating. Regular inspection for belt tension, crack and wear status is mandatory for belt‑driven model. Belts belong to wearing consumable parts.
Important performance boundary note: 19.8 m³/min is nominal flow‑rate under standardized reference‑conditions. Actual free‑air delivery will decrease when working under high‑ambient‑temperature or high‑altitude location. Site‑operating‑condition data is required for pre‑order performance evaluation to avoid on‑site capacity mismatch.
Unit‑type characteristic reminder: This is fixed‑speed (on/off / load‑unload control) compressor. It shows acceptable energy‑efficiency under stable full‑load continuous‑running condition. Under partial‑load, fixed‑speed design brings relatively higher power‑consumption compared with VSD variable‑speed drive compressor. It is more suitable for workshops with steady air‑demand; not the best option for sites with heavily fluctuating compressed‑air consumption.
Field‑service troubleshooting note: Insufficient air‑output or frequent high‑discharge‑temperature alarm does not automatically mean defective screw air‑end. Technicians should finish upstream inspection workflow: check belt slipping & wear condition → inspect intake filter clogging → verify oil‑cooler fouling → test thermostatic‑valve function, before judging air‑end failure.
Critical buying alert: Model designation JRZ‑150AZ/0.8 alone cannot guarantee perfect site‑fit. Please submit site‑information for our pre‑order technical evaluation: site altitude, maximum ambient‑temperature, real‑peak air‑consumption, local power‑supply specification, downstream air‑treatment requirement(dryer / filter or not). Avoid unsatisfactory on‑site performance and production‑downtime.
Customer Buying & Maintenance Priorities
Industrial buyers evaluating 110 kW belt‑drive screw compressor consider multi‑dimensional practical concerns beyond unit price. Below key practical concerns are fully addressed within this page:
1. Site‑fit‑evaluation risk: Nominal flow is reference‑condition value; high‑altitude / high‑temp environment reduces real air‑output; submit site‑data before quotation.
2. Belt‑drive specific awareness: Belt slipping / aging leads to low air‑output & over‑heat; periodic tension & wear inspection required; belt is wearing consumable.
3. Fault‑diagnosis workflow: Avoid direct air‑end condemnation; inspect belt condition, intake filter, cooler fouling and thermostatic‑valve when facing low‑output / high‑temp alarm.
4. Unit‑type characteristic awareness: Fixed‑speed design fits stable continuous‑air‑demand; partial‑load power‑consumption disadvantage versus VSD compressor.
5. System‑matching awareness: Oil‑injected compressor cannot deliver Class0 oil‑free air; dryer & filter must be ordered separately for high‑purity‑process.
6. Warranty‑scope clarity: Main‑unit manufacturing‑defect coverage; exclude wearing‑consumables(belt, filter‑elements, compressor oil); damage caused by wrong‑installation, abnormal‑power‑supply, harsh‑site‑environment; onsite commissioning labor and return‑freight not included.
7. Project‑order support: For system integrators & large‑plant projects, export‑grade fumigated wooden‑crate packing, test‑report & shipping‑document support; optional spare‑consumable‑kit.
8. Technical‑backup: Provide installation‑layout hint and routine‑maintenance checklist for on‑site technicians.
Compatibility & Pre‑Order Site‑Condition Checklist
Model:JRZ‑150AZ/0.8
Product Type:Belt‑Drive Single‑Stage Fixed‑Speed Oil‑Injected Screw Air Compressor
Rated Motor Power:110 kW
Nominal Free‑Air Delivery:19.8 m³/min @0.8 MPa(reference‑condition)
Working Pressure:0.8 MPa
Cooling Method:Air‑Cooled
Standard Power‑Supply:380 V / 50 Hz 3‑Phase
Noise Level:88±2 dB(A)
Information we require before quotation:
1. Site altitude & maximum summer ambient‑temperature
2. Actual peak & average compressed‑air consumption
3. Local power‑supply voltage / frequency
4. Down‑stream requirement: whether need refrigerated‑dryer, line‑filters, air‑receiver tank
5. Working‑pattern: 24h continuous‑run or intermittent operation
6. Order‑type: single‑unit replacement / new‑plant project / with spare‑consumable‑kit
Order‑decision reference
‑ Prefer this model: Site with stable continuous air‑demand, air‑cooling condition available, no heavily fluctuating partial‑load working cycle.
‑ Need further re‑evaluation: High‑altitude, persistent high‑ambient‑temp; large‑range fluctuating air‑consumption; require ISO8573‑1 Class0 oil‑free compressed‑air.
Core Functional Benefits
1. Belt‑drive transmission for robust industrial‑site adaptability
Heavy‑duty industrial V‑belt transmission system, designed for 20000‑hour reference service‑life under normal maintenance. Belt‑drive layout facilitates disassembly‑access for belt replacement and routine service work.
Note: Belt‑drive requires periodic tension adjustment & wear inspection to maintain rated air‑output performance.
2. Schneider PLC‑based automatic control system
Equipped with Schneider PLC + local touch‑screen HMI. Real‑time monitoring for discharge‑pressure, oil‑temperature, running‑hours, fault‑alarm logging. Load‑unload automatic cycle control; multiple protection: over‑temp, over‑current, over‑pressure protection for safe operation.
3. Easy‑access canopy‑frame for maintenance
Side panels can be quickly opened, provides convenient access for intake‑filter, oil‑filter, oil‑separator replacement. Reduces time spent on routine consumable‑parts service.
4. Air‑cooled integrated cooling package
Large‑size air‑cooled radiator assembly, fits sites without cooling‑water resource. Depends on workshop ventilation condition; sufficient surrounding clearance must be reserved for heat dissipation during installation.
5. Vibration‑damping mounting feet
Built‑in vibration‑damping mounts, reduce vibration transmission to foundation and lower secondary noise radiation for workshop environment.
Technical Specification
| Parameter | Value |
|---|---|
| Model | JRZ‑150AZ/0.8 |
| Type | Belt‑Drive Single‑Stage Fixed‑Speed Screw Air Compressor |
| Rated Motor Power | 110 kW |
| Nominal Free‑Air Delivery | 19.8 m³/min @0.8 MPa (reference‑condition) |
| Rated Working Pressure | 0.8 MPa |
| Cooling Method | Air‑Cooled |
| Motor Rotational Speed | 2980 r/min |
| Standard Power‑Supply | 380 V‑50 Hz 3‑Phase |
| Noise Level | 88±2 dB(A) |
| Control System | Schneider PLC + Touch‑Screen HMI |
| Transmission Type | Industrial V‑Belt Drive (consumable part) |
| MOQ | 1 Unit |
| Shipment Option | Sea‑freight with export fumigated wooden crate, air‑freight |
| Payment Terms | T/T, PayPal, Western Union |
| Important Remark | Nominal flow reduces at high‑altitude / high‑temp; belt needs periodic inspection; NOT ISO8573‑1 Class0 oil‑free unit |
Good Customers Reviews

Risk Of Mis‑Application & Wrong‑Site‑Selection
Selecting compressor only by nominal catalog parameters will bring hidden production‑site risk:
1. Ignoring altitude & ambient‑temperature influence: Directly use 19.8 m³/min catalog value for high‑altitude / hot‑workshop, real‑world air‑output drops, cannot satisfy production‑peak air‑demand.
2. Mis‑application for heavily‑fluctuating air‑demand: Fixed‑speed unit works inefficient under frequent partial‑load condition, resulting in long‑term extra electricity‑cost compared with VSD variable‑speed compressor.
3. Misunderstanding air‑quality performance: Expecting oil‑injected unit to deliver ISO8573‑1 Class0 oil‑free compressed‑air; must purchase separate dryer‑filter system for high‑purity process.
4. Neglecting belt‑drive maintenance: Skipping periodic belt‑inspection; belt slipping / cracking leads to output‑drop, over‑heating and unexpected breakdown.
Cost insight: Up‑front savings by mis‑matching compressor model for your real‑site condition may cause persistent high‑power‑consumption, insufficient air‑supply and production‑line loss. Compressor selection is a system‑level decision instead of only checking catalog power & flow figures.
Typical Application Scenarios
This JRZ‑150AZ/0.8 belt‑drive screw compressor is suitable for industrial‑facilities with relatively stable continuous compressed‑air consumption:
‑ General‑manufacturing & metal‑fabrication workshops
‑ Automotive assembly & paint‑shops
‑ Plastic‑injection & extrusion production‑lines
‑ 24‑hour continuous‑run light‑industry compressed‑air‑stations
‑ Compressed‑air system integrators, factory‑new‑project & equipment‑renewal
Reminder: This oil‑injected unit itself cannot provide ISO8573‑1 Class0 oil‑free compressed‑air. Laser‑cutting or high‑purity‑process application needs matched downstream dryer‑filter package as additional order item. Not recommended for sites with dramatic short‑term air‑consumption fluctuation.
Critical On‑Site Installation, Commissioning & Routine‑Maintenance Guidance
Safety Warning: Strictly perform full LOTO lock‑out‑tag‑out procedure. Cut‑off full power‑supply before opening belt‑guard or service panels. Rotating components and hot surfaces present personal‑injury hazard.
1. Pre‑installation site‑preparation
Place unit on solid, level concrete foundation. Reserve sufficient surrounding ventilation clearance for air‑cooled radiator heat dissipation. Guarantee workshop ambient‑temperature within 5‑40℃ range. Confirm on‑site power‑supply matches unit rated specification; complete reliable equipment grounding work. Compressed‑air outlet piping shall adopt pressure‑rated pipeline, install isolation‑valve & check‑valve at compressor outlet.
2. Pre‑start‑up check before commissioning
Check lubricant oil level at sight‑glass; inspect belt tension, no crack / fray damage; check all filter‑element status; confirm cooling‑radiator fin without heavy dust blockage. All safety‑guards including belt‑guard must be correctly installed before power‑on.
3. Unit commissioning & baseline‑recording
Power‑on, execute no‑load test‑run firstly, then switch to loaded operation. Monitor discharge‑pressure, oil‑temperature, running current under stable full‑load. Record baseline working data: actual output pressure, steady oil‑temperature, running‑current for future‑maintenance reference. Check piping joint for air‑leakage.
4. Key periodic‑maintenance points for belt‑drive model
‑ Check V‑belt tension, crack, fray wear status periodically; adjust tension or replace belt as required.
‑ Replace intake‑filter / oil‑filter / oil‑separator / compressor‑oil following service‑schedule.
‑ Clean dust fouling on air‑cooled radiator fins to avoid high‑temperature trip.
‑ Check PLC fault history log, resolve early warning fault before breakdown occurs.
5. Troubleshooting hint after commissioning
If compressor suffers low air‑output or frequent high‑oil‑temperature trip: Do NOT judge screw air‑end defective directly. Re‑inspect belt slipping / wear, intake‑filter blockage, radiator fouling and thermostatic‑valve working‑status. Many abnormal‑operation issues root in transmission & peripheral components.
Project‑Order & Spare‑Part Planning Guidance
For factory‑maintenance‑teams, compressed‑air‑system integrators:
1. Single‑unit emergency‑replacement: Sea‑freight / air‑freight delivery for equipment‑renewal project.
2. Large‑plant new‑construction bulk‑order: Project‑based quotation; export fumigated wooden‑crate packing; provide shipping‑documents & test‑report support.
3. Optional combined‑package: Match with intake‑filter / oil‑filter / oil‑separator consumable‑kit, or supporting refrigerated‑dryer, air‑receiver tank, inline‑filter set for one‑stop compressed‑air‑system solution.
4. Reserved‑stock‑program: We can reserve critical spare‑parts against global supply‑chain fluctuation for regular‑customers.
5. Pre‑shipment‑inspection: Factory running‑test before packing for project‑order; inspection photos available upon request.
Inventory suggestion: Keep critical wearing‑spares(V‑belt, filter‑elements) on‑site for 24‑h continuous‑production factory.
Frequently Asked Questions
Q1: Can JRZ‑150AZ/0.8 provide ISO8573‑1 Class0 oil‑free compressed‑air for laser‑cutting?
A: No. This is oil‑injected screw compressor unit. To achieve high‑purity compressed‑air for laser‑cutting, you need to additionally order downstream refrigerated‑dryer and multi‑stage coalescing filter assembly. Class0 oil‑free air requires dedicated oil‑free compressor unit.
Q2: The catalog shows 19.8 m³/min output, can I get this flow at high‑altitude / hot‑workshop?
A: 19.8 m³/min is nominal value under standardized reference‑conditions. Actual free‑air‑delivery decreases when site is at high‑altitude or with persistent high‑ambient‑temperature. Please send site‑condition data for our pre‑order performance evaluation.
Q3: Why my belt‑drive screw compressor air‑output gradually drops?
A: Most‑frequent causes: V‑belt slipping / aging‑wear; clogged intake‑air‑filter; radiator fouling; thermostatic‑valve abnormal. Inspect transmission‑system first, do not directly suspect screw air‑end damage.
Q4: Is fixed‑speed JRZ‑150AZ/0.8 suitable for site with big fluctuation of air‑consumption?
A: Not ideal. Fixed‑speed compressor has higher partial‑‑load power‑consumption. For heavily‑fluctuating air‑demand, VSD variable‑speed screw compressor is better‑suited solution. This model is recommended for relatively stable continuous‑air‑demand.
Q5: What regular maintenance items are special for belt‑drive screw compressor?
A: Except common three‑filter & oil replacement; you must periodically inspect V‑belt tension, crack and fray wear. Improper belt‑condition will cause output‑reduction and over‑heating fault. Belt is wearing consumable part.
Q6: What damage situation is excluded under limited product warranty?
A: Limited‑product‑warranty only covers main‑unit manufacturing‑related defects. Excluded: wearing‑consumables(V‑belt, filter‑elements, compressor‑oil); damage from wrong‑installation, abnormal‑power‑supply, harsh‑site‑environment; onsite commissioning labor and return‑shipment freight are not included.
Request Technical Quotation for JRZ‑150AZ/0.8 110 kW Belt‑Drive Screw Compressor
Fill inquiry‑form with full site‑condition information, downstream‑equipment‑requirement, quantity and destination‑country. Our sales‑engineer will reply quotation and lead‑time promptly.
Hot Tags: JRZ‑150AZ/0.8 Belt‑Drive Screw Compressor 110kW 19.8m³/min, China JRZ‑150AZ/0.8 Belt‑Drive Screw Compressor 110kW 19.8m³/min manufacturers, suppliers

