Product Overview
Part number 2906009200 is complete replacement filter‑element kit for Atlas Copco compressed‑air pipeline filter housing. This kit is installed on downstream compressed‑air pipeline after air‑oil separator and dryer, NOT at compressor intake air inlet. This multi‑stage kit combines particle‑filtration, coalescing and activated‑carbon media, sequentially removing solid dust, liquid water droplets and oil aerosol from treated compressed‑air, protecting downstream pneumatic actuators, valves and production‑process equipment from contamination damage.
Critical hardware note: Bypass‑valve function belongs to filter housing assembly, NOT included inside this 2906009200 filter‑element kit. If your system requires on‑line servicing without shutting‑down air flow, the complete bypass hardware shall be purchased separately for filter housing.
Very important field‑service reminder: Persistent oil or water contamination appearing in end‑user compressed‑air does not automatically mean this filter‑element kit is defective. Before ordering new spare kit, technicians shall complete upstream troubleshooting workflow: inspect compressor oil‑separator for oil‑carry‑over fault, verify refrigerated‑dryer working performance, check pipeline condensed‑water accumulation. Many compressed‑air quality complaints root in upstream compressor / dryer hardware instead of line filter‑elements.
Many maintenance teams only follow fixed running‑hour counter for filter replacement. 8000 operating‑hour rating is only reference benchmark under clean, low‑oil‑aerosol indoor workshop. Under heavy‑oil‑carry‑over, high‑humidity or poor dryer performance condition, filter media will saturate far ahead of reference runtime. Filter‑kit differential‑pressure reading is primary replacement trigger instead of runtime counter only.
Important maintenance warning: Elements within this 2906009200 kit cannot be blow‑cleaned for repeated reuse. Pressurized air‑blowing creates invisible micro‑tears and structural damage on glass‑fiber coalescing media and activated‑carbon layer. Damaged media will produce contaminant bypass risk. Full kit replacement is mandatory once differential‑pressure reaches OEM alarm threshold.
Critical buying alert: Part‑number 2906009200 alone cannot guarantee perfect fitment. Different Atlas Copco filter‑housing hardware revisions bring minor difference on O‑ring sealing dimension. Always submit full compressor serial‑number plus photo of old filter‑kit marking for our technical cross‑verification before placing your order, avoid mis‑fit and costly production‑downtime.

Customer Buying & Maintenance Priorities
Industrial maintenance buyers sourcing Atlas Copco line filter‑element kit consider multi‑dimensional practical concerns beyond unit price. Below key practical concerns are fully addressed within this page:
1. Fitment‑accuracy risk: Same part‑number may contain housing‑revision differences for O‑ring sealing dimension; serial‑number cross‑validation required to prevent wrong‑part delivery.
2. Fault‑diagnosis workflow: Avoid blind filter‑kit replacement; inspect upstream oil‑separator, dryer performance and pipeline condensed‑water when facing compressed‑air oil‑water contamination.
3. Forbidden maintenance‑operation: Understand why compressed‑air blow‑clean must never be performed on these filter elements.
4. Installation‑risk awareness: Discard all old O‑ring gaskets completely; install brand‑new matching seals; strictly follow air‑flow arrow‑direction on elements.
5. Replacement‑criteria logic: Judge replacement by filter‑kit differential‑pressure value instead of blindly following fixed running‑hour schedule.
6. Consumable awareness: Filter‑elements are wearing consumables; upstream oil‑carry‑over can saturate whole kit within very short runtime.
7. Warranty‑scope clarity: Manufacturing‑defect coverage for filter‑elements; exclude element saturation caused by upstream oil / condensed‑water contamination; onsite labor and return‑shipment freight are not included.
8. Bulk‑order support: For compressor‑service contractors, pre‑shipment visual‑inspection and export‑grade packing.
9. Technical‑backup: Installation and compressed‑air‑quality troubleshooting reference checklist for on‑site maintenance technicians.
Compatibility & Pre‑Order Verification Checklist
OEM Part Number:2906009200
Product Type:Multi‑Stage Line Filter‑Element Replacement Kit
Applicable Equipment:Matched Atlas Copco compressed‑air pipeline filter housing (post‑compressor downstream side)
Information we require before quotation:
1. Full compressor serial‑number from machine name‑plate
2. Clear photo of old filter‑kit marking (if available)
3. Fault‑symptom description (if applicable): high filter differential‑pressure / end‑air oil‑water contamination etc.
4. Working‑site environment: indoor / high‑humidity / heavy oil‑aerosol risk / 24‑h continuous‑running
5. Order requirement: single emergency spare / bulk‑stock for service‑fleet
Replacement‑decision reference
‑ Mandatory replacement: Filter‑kit differential‑pressure reaches OEM alarm threshold, media saturated by oil / water.
‑ Further system inspection recommended: Poor compressed‑air quality occurs; inspect upstream oil‑separator, dryer and pipeline drainage status before filter‑kit swap‑out.
Core Functional Benefits
1. Multi‑stage sequential purification for downstream compressed‑air
Combined multi‑media construction: particle‑removal pleated media, glass‑fiber coalescing layer and activated‑carbon stage. Step‑by‑step captures solid particles, liquid water droplets and oil aerosol in compressed‑air. Protect downstream pneumatic components, painting equipment and process production devices against contamination.
2. Control pipeline‑side differential‑pressure loss
Optimized media layout maintains low initial differential‑pressure. As dust, oil and water contaminants accumulate inside filter‑kit, pressure‑drop rises and creates extra system energy‑loss. Timely filter‑kit replacement keeps pipeline pressure‑loss within OEM baseline.
3. Complete matching sealing‑O‑rings included in kit
Each 2906009200 kit comes supplied with brand‑new dedicated O‑ring sealing gaskets. Never reuse aged old O‑rings. After long‑term pressure‑temperature cycling, old O‑rings harden and deform, creating hidden contaminant‑bypass gap, compressed‑air will skip filter‑media protection even with brand‑new filter‑elements.
4. Drop‑in replacement for original Atlas Copco filter‑housing
Outer dimension and sealing footprint matches OEM filter‑housing assembly. No housing‑modification required during swap‑out.
Mandatory installation note: Follow air‑flow arrow marking printed on filter‑element body for correct mounting direction; reversed installation will completely lose purification performance.
5. Reduce whole downstream system‑maintenance expense
Qualified multi‑stage filter‑kit stabilizes end‑compressed‑air quality, lowers failure rate of downstream valves, cylinders and process equipment; extends service‑life of post‑processing consumable spare‑parts.
Technical Specification
| Parameter | Value |
|---|---|
| Part Number | 2906009200 |
| Type | Multi‑Stage Line Filter‑Element Replacement Kit |
| Media Composition | Pleated particle‑filter media, glass‑fiber coalescing layer, activated‑carbon |
| Max working pressure | 16 bar |
| Working temperature | ‑20℃ ~ +80℃ |
| Reference service‑life | 8000 hrs (clean low‑oil‑aerosol workshop reference‑only) |
| Sealing | Matching O‑ring gaskets included |
| Reusability | Single‑use only; Do NOT blow‑clean elements for reuse |
| Mounting position | Downstream compressed‑air pipeline (after compressor air‑oil separator & dryer) |
| MOQ | 1 Piece / Kit |
| Shipment Option | DHL/FedEx/UPS express, air freight, sea freight |
| Payment Terms | T/T, PayPal, Western Union |
| Important Remark | Bypass‑valve not included in this kit; strictly follow element air‑flow arrow‑direction; filter‑elements are consumables |
Good Customers reviews

Risk Of Low‑Grade Aftermarket Filter‑Kit
Selecting filter‑kit purely based on low purchase‑price brings significant hidden risk for your compressed‑air system asset:
1. Sub‑standard composite filter‑media: Early saturation, poor oil‑aerosol / water droplet holding‑capacity, compressed‑air quality fails application requirement.
2. Inferior activated‑carbon & coalescing glass‑fiber: Media degrades quickly under oil‑mist exposure, shedding fine particles into downstream air pipeline.
3. Poor‑quality O‑ring gasket compound: O‑ring ages fast under pressure‑temperature cycling, creates hidden contaminant‑bypass gap.
4. Wrong physical dimension tolerance: Element cannot seat properly inside filter housing, permanent bypass leakage risk.
Cost insight: Saving small upfront cost on cheap filter‑kit can lead to expensive damage on downstream pneumatic and production equipment. Downstream line filter‑kit acts as critical final‑stage protection barrier for your compressed‑air quality.
Typical Application Scenarios
This 2906009200 line filter‑element kit serves industrial facilities operating matched Atlas Copco compressed‑air pipeline filter housings:
‑ General‑manufacturing & metal‑fabrication workshops
‑ Automotive assembly and paint‑spray production‑lines
‑ Plastic‑injection & extrusion factories
‑ 24‑hour continuous‑run light‑industry compressed‑air‑stations
‑ Compressor‑service & rental‑companies for maintenance‑spare‑parts stocking
Evaluate filter‑kit replacement project when you observe rising filter‑housing differential‑pressure reading or unstable end‑compressed‑air purity. Always inspect O‑ring gasket integrity and air‑flow‑direction during each filter‑kit‑maintenance cycle.
Reminder: This kit fits post‑compressor downstream pipeline filter housing, NOT compressor intake air filter assembly. Not designed for direct installation on pneumatic drill / air‑separation main‑equipment.
Critical On‑Site Installation & Post‑Replacement Guidance
Safety Warning: Strictly perform full LOTO lock‑out‑tag‑out procedure. Shut‑down air supply and fully depressurize filter housing before opening housing cover. Compressed‑air residual pressure may cause personal injury.
1. Pre‑installation housing‑preparation
Isolate and fully depressurize filter housing. Open housing cover, take out old filter‑elements. Completely peel‑off and discard all aged old O‑ring gaskets. Thoroughly clean oil‑water sludge and debris inside filter‑housing cavity. Inspect upstream pipeline drainage performance at this maintenance window.
2. New filter‑kit installation work Fit brand‑new matching O‑ring seals. Install each filter‑element from 2906009200 kit, strictly follow air‑flow arrow marking on each element body for correct mounting direction. Close housing cover and evenly tighten housing fasteners; avoid over‑torque cracking housing.
3. Post‑start‑up observation & baseline‑recording
Restore compressed‑air supply. Run system under stable working‑condition for 60‑90 minutes.
‑ Inspect housing joint for air‑leakage;
‑ Record baseline filter‑kit differential‑pressure reading for future‑maintenance reference;
‑ Monitor end‑compressed‑air quality status.
4. System‑maintenance recommendation
If removed old filter‑kit is heavily contaminated by oil or water, solve upstream root‑cause: check oil‑separator oil‑carry‑over, dryer performance and pipeline drain system. Otherwise new filter‑kit will saturate within short runtime.
5. Troubleshooting hint after replacement
If poor compressed‑air oil‑water contamination still exists after fitting brand‑new 2906009200 filter‑kit: Do NOT judge filter‑kit defective directly. Re‑check upstream oil‑separator condition, refrigerated‑dryer operation and pipeline condensed‑water drainage. Most air‑quality issues root in upstream components instead of filter‑kit itself.
Spare‑Part Planning & Bulk‑Procurement Guidance
For factory‑maintenance‑teams, compressed‑air‑system integrators and compressor‑service‑contractors:
1. Emergency single‑kit order: Fast express‑shipment for sudden filter‑related breakdown to minimize production‑downtime.
2. Quarterly / annual bulk‑procurement: Planned preventive‑maintenance stocking, better unit‑price and stable lead‑time.
3. Combined‑consumable‑kit: Bundle together with compressor air‑filter, oil‑filter, oil‑separator for complete overhaul‑package, reduce per‑item shipping‑cost.
4. Reserved‑stock‑program: We can reserve inventory for regular‑customers against global spare‑part supply‑fluctuation.
5. Pre‑shipment‑inspection: Visual‑check filter‑element media integrity and O‑ring condition; bulk‑order inspection‑photos available upon request.
Inventory suggestion: Keep spare 2906009200 filter‑kit onsite for critical 24‑h production compressed‑air systems, especially for paint‑shop and high‑purity‑process application.
Frequently Asked Questions
Q1: My end compressed‑air contains oil / water, should I directly order 2906009200 filter‑kit for replacement?
A: Blind replacement is not recommended. Please inspect upstream compressor oil‑separator for oil‑carry‑over, refrigerated‑dryer working performance and pipeline condensed‑water drainage first. Many air‑quality faults come from upstream system instead of filter‑kit.
Q2: Must I replace filter‑kit exactly at 8000 running‑hours?
A: 8000‑hour rating is reference‑value under clean low‑oil‑aerosol workshop environment. High‑humidity or upstream oil‑pollution will shorten practical‑service‑life. Filter‑kit differential‑pressure alarm‑threshold takes higher priority than runtime counter.
Q3: Can I blow‑clean used filter‑elements from 2906009200 kit with compressed‑air for re‑use?
A: Not allowed. Compressed‑air blasting creates invisible micro‑tears and structural damage on coalescing / activated‑carbon media, leads to contaminant bypass risk. Filter‑kit is designed for single‑use full‑replacement.
Q4: Does 2906009200 contain bypass‑valve assembly?
A: No. Bypass‑valve belongs to filter‑housing hardware, not included within this filter‑element replacement kit.
Q5: Does part‑number 2906009200 fit every Atlas Copco filter housing?
A: No. Different filter‑housing hardware‑revisions may have O‑ring sealing dimension differences. Submit full compressor serial‑number for compatibility cross‑check before ordering.
Q6: What risk will happen if I reuse old O‑ring gaskets during filter‑kit change‑out?
A: Aged O‑ring loses elasticity after pressure‑temperature cycling. It creates hidden contaminant‑bypass gap; polluted compressed‑air bypass filter‑media directly to downstream equipment, even with brand‑new filter‑elements. Always fit brand‑new matching O‑ring seals.
Q7: What damage situation is excluded under limited product warranty?
A: Limited‑product‑warranty only covers filter‑element manufacturing‑related defects. Excluded: element saturation caused by upstream oil / condensed‑water contamination; onsite commissioning labor and return‑shipment freight are not included.
Request Technical Quotation for 2906009200 Filter‑Element Kit
Fill inquiry‑form with compressor serial‑number, fault‑description, quantity and destination‑country. Our sales‑engineer will reply quotation and lead‑time promptly.
Hot Tags: 2906009200 Line Filter‑Element Kit | Atlas Copco Compressed‑Air, China 2906009200 Line Filter‑Element Kit | Atlas Copco Compressed‑Air manufacturers, suppliers, Atlas Copco Air Filter Kit, 2901086501, 2901920010, 1621138900, Atlas Air Compressor Air Filter Element, Replacement Air Filter For Atlas Copco Air Compressor