Product Overview
Part number 7.1360.0 is a 3‑2‑way pilot‑type solenoid valve exclusively developed for matched Kaeser oil‑injected rotary screw compressors. It serves as core pneumatic pilot control component, executing inlet‑valve loading, unloading and separator‑tank blow‑down vent sequence according to Sigma‑Control controller output signal.
Critical hardware note: This is compressor‑specialized pilot solenoid valve. It is NOT general‑purpose automation valve for robot, food‑packaging or medical‑equipment. Working medium must be clean pilot compressed‑air inside compressor cabinet only.
Very important compatibility reminder: Identical part‑number 7.1360.0 comes with multiple factory coil‑voltage variants: 24 VDC / 110 V AC / 230 V AC. Wrong supply‑voltage will burn coil instantly. DIN43650 electrical connector may contain built‑in free‑wheeling diode; mismatched diode configuration can damage Sigma‑Control controller IO output ports.
Common field fault symptoms related to this pilot solenoid:
‑ Compressor cannot load or fail to unload at pressure set‑point
‑ Continuous blow‑down air leakage after compressor shutdown
‑ Rapid frequent load‑unload pressure oscillation
‑ No pilot air actuation even receiving controller output signal
Critical troubleshooting reminder (real‑world service lesson): Above‑mentioned symptoms do not automatically mean solenoid valve defective. Technicians should complete diagnostic steps in correct sequence: verify controller output signal → measure actual coil supply‑voltage → inspect pilot tubing for oil‑carbon sludge blockage → then judge solenoid‑valve spool / coil damage. Many load‑unload failures root in upstream electrical or piping condition, not valve itself. Blind replacement of solenoid will not resolve system‑level faults.
Critical buying alert: Part‑number 7.1360.0 alone cannot guarantee perfect fitment. Coil‑voltage variant and DIN‑connector internal specification vary for different Kaeser compressor hardware revisions. Always submit full compressor serial‑number plus photo of old solenoid‑valve name‑plate for our technical cross‑verification before placing your order, avoid wrong‑part shipment and costly production downtime.
Customer Buying & Maintenance Priorities
Industrial maintenance buyers sourcing Kaeser pilot solenoid valve consider multi‑dimensional practical concerns beyond unit price:
1. Fitment accuracy risk: Coil‑voltage is primary matching parameter; same PN has multiple voltage variants, serial‑number cross‑validation required.
2. Fault‑diagnosis workflow: Avoid blind valve replacement; check controller signal, coil voltage and pilot tubing sludge clog before ordering spare‑part.
3. Electrical safety rule: Strictly prohibit hot‑swap DIN43650 connector under powered‑on status; hot‑swap may burn coil or controller IO‑port.
4. Medium requirement awareness: Pilot air must be clean; oil‑carbon sludge inside tubing will cause spool sticking and intermittent valve failure.
5. Assembly risk awareness: Do not over‑torque threaded port; over‑tightening cracks brass / composite valve‑body.
6. Warranty scope clarity: Only covers manufacturing‑related defects of valve assembly. Exclude coil burn‑out by wrong‑voltage, hot‑swap damage, sludge‑caused spool sticking, installation mechanical abuse; onsite labor and return‑shipment freight are not included.
7. Bulk‑order support: For compressor‑service contractors, pre‑shipment coil‑resistance spot‑check, anti‑static export‑grade packing.
8. Technical backup: Field troubleshooting checklist for onsite maintenance technicians.
Compatibility & Pre‑Order Verification Checklist
OEM Part Number:7.1360.0
Product Type:3‑2‑Way Pilot Solenoid Valve
Available Coil‑Voltage Variant:24 VDC / 110 V AC / 230 V AC
Electrical Connector:DIN43650 Form‑B
Applicable Equipment:Matched Kaeser oil‑injected rotary screw compressor (for inlet‑valve load‑unload & blow‑down pilot control)
Information we require before quotation:
1. Full compressor serial‑number from machine name‑plate
2. Clear photo of original old solenoid‑valve name‑plate (coil‑voltage marking)
3. Fault‑symptom description: no‑load / continuous blow‑down / pressure‑oscillation etc.
4. Confirm existing coil‑voltage specification of old valve
Replacement decision reference
‑ Order new 7.1360.0 solenoid: Confirmed coil burnout, spool mechanical seizure, valve‑body thread crack after full upstream troubleshooting.
‑ Do NOT order blindly: When pilot‑tubing heavily clogged, controller output abnormal; fix upstream root‑cause first.
Core Functional Benefits
1. Reliable pilot‑air switching for load‑unload & blow‑‑down sequence
7.1360.0 pilot solenoid receives trigger signal from Sigma‑Control HMI, switches pilot compressed‑air path accurately. It controls inlet‑valve actuation for loading‑unloading and executes separator‑tank blow‑down vent on shutdown, stabilizes system working pressure for production‑side pneumatic equipment.
2. Industrial‑grade spool & sealing compound for compressor‑cabinet environment
Spool and seal formulation resists trace oil‑mist inside compressor pilot‑air circuit, adapts cabinet vibration and moderate temperature fluctuation inside Kaeser compressor electrical cabinet.
3. DIN43650 standard industrial connector
Matches original Kaeser wiring harness connector layout. No large‑scale wiring modification required during swap‑out. Mandatory rule: Always cut off full power supply before disconnecting DIN connector, hot‑swap forbidden.
4. Drop‑in thread‑port replacement
G1/4 thread port dimension matches OEM pilot‑circuit piping layout. No adapter modification required. Observe correct torque‑limit to avoid valve‑body cracking.
5. Avoid secondary component damage
Qualified pilot solenoid ensures correct load‑unload timing. Prevent frequent abnormal cycling which accelerates wear of inlet‑valve diaphragm and other pneumatic control parts of Kaeser screw compressor.

Technical Specification
| Parameter | Value |
|---|---|
| Part Number | 7.1360.0 |
| Valve Type | 3‑2‑Way Pilot Solenoid Valve |
| Available Coil Voltage | 24 VDC / 110 V AC / 230 V AC (specify before order) |
| Electrical Connector | DIN43650 Form‑B |
| Working Medium | Clean pilot compressed‑air only (no heavy oil‑sludge) |
| Max working pressure | 0‑16 bar |
| Ambient temperature | ‑10℃ ~ +50℃ |
| Thread Port | G1/4" |
| MOQ | 1 Piece |
| Shipment Option | DHL/FedEx/UPS express, air freight, sea freight |
| Payment Terms | T/T, PayPal, Western Union |
| Important Remark | Not general‑purpose automation valve; NO hot‑swap DIN connector; specify coil‑voltage upon ordering |
Good Customers Reviews

Risk Of Mis‑application & Low‑Grade Aftermarket Solenoid Valve
1. Wrong coil‑voltage selection
Installing mismatched coil‑voltage burns coil within short time; damage is excluded under product warranty. Same part‑number does NOT mean same coil‑spec.
2. Hot‑swap DIN43650 connector under powered‑on
Live disconnection creates inductive surge; burns solenoid coil or even Sigma‑Control controller IO output circuit, causes extended compressor downtime.
3. Dirty pilot‑air with heavy carbon‑sludge
Even brand‑new high‑quality solenoid valve will suffer spool sticking and intermittent failure if pilot tubing carries large‑amount oil‑carbon sludge. Replacing solenoid cannot solve contaminated pilot‑circuit root‑cause.
4. Over‑torque threaded port during installation
Excessive wrench force cracks composite / brass valve‑body, generates hidden internal or external air‑leakage fault.
5. Low‑grade generic aftermarket solenoid
Cheap substitute may ignore free‑wheeling‑diode requirement for Kaeser Sigma‑Control IO output, creates signal interference or controller port damage; inferior seal material ages fast under compressor oil‑mist environment, leads to early spool‑sticking failure.
Cost insight: Low‑cost solenoid saves small upfront expense. But repeated compressor cycling, controller‑port burn‑out and production downtime will create many‑times‑higher indirect loss.
Typical Application Scenarios
This 7.1360.0 pilot solenoid‑valve serves industrial facilities running matched Kaeser oil‑injected rotary screw compressors:
‑ General manufacturing & metal‑working workshops
‑ Automotive assembly & painting facilities
‑ Plastic‑processing production‑lines
‑ 24‑hour continuous‑run light‑industry compressed‑air stations
‑ Compressor service & rental companies for maintenance spare‑parts stocking
Evaluate solenoid‑valve replacement after completing upstream troubleshooting, when you observe: compressor cannot load‑unload, continuous blow‑‑down leakage, frequent pressure oscillation.
Critical On‑Site Installation & Post‑Replacement Guidance
Safety Warning: Strictly perform full LOTO lock‑out‑tag‑out procedure. Fully cut compressor control power‑supply before disconnecting DIN43650 electrical connector. Hot‑swap under powered‑on is strictly forbidden. Release residual pressure from pilot‑air circuit before piping disassembly.
1. Pre‑installation system preparation
Power‑off compressor, release pilot‑circuit residual pressure. Disconnect DIN electrical connector and G1/4 pilot tubing. Remove old solenoid‑valve. Inspect pilot tubing for carbon‑sludge contamination; heavily contaminated tubing should be cleaned or replaced.
2. New solenoid‑valve mounting & piping connection
Install brand‑new 7.1360.0 pilot solenoid‑valve. Connect pilot thread port; follow service‑manual torque‑specification, avoid over‑torque cracking valve‑body. Re‑fit DIN43650 connector and lock correctly. Double‑check coil‑voltage matches cabinet power‑supply.
3. Post‑start‑up functional commissioning
Restore compressor control‑power supply. Run compressor and execute complete pressure‑cycle test:
‑ Verify correct loading‑action at cut‑in pressure;
‑ Verify unloading‑action and blow‑‑down vent performance at cut‑out pressure;
‑ Inspect thread‑port and connector for air‑leakage;
‑ Observe whether abnormal frequent load‑unload oscillation disappears;
‑ Record baseline working status for future‑maintenance reference.
4. Troubleshooting hint after replacement If load‑unload fault still exists after new solenoid‑valve installation: Do NOT judge valve defective directly. Re‑inspect: Sigma‑Control controller output signal, actual coil supply‑voltage, pilot‑tube sludge clogging, inlet‑valve diaphragm condition. Many faults come from upstream components.
Spare‑Part Planning & Bulk‑Procurement Guidance
For factory‑maintenance‑teams and compressor‑service‑contractors:
1. Emergency single‑order: Fast express shipment for sudden pneumatic‑control breakdown, minimize production‑downtime.
2. Quarterly / annual bulk‑procurement: Planned maintenance project, better unit‑price and stable lead‑time. Please clearly specify required coil‑voltage when placing bulk‑order.
3. Combined‑consumable‑kit: Bundle pilot solenoid with matched inlet‑valve repair kit and other pneumatic spare‑parts for overhaul‑project.
4. Pre‑shipment inspection: Coil resistance spot‑check, visual inspection for valve‑body thread integrity; bulk‑order inspection photos available upon request.
Inventory suggestion: Keep spare pilot solenoid (confirm correct coil‑voltage) onsite for critical 24‑hour‑running Kaeser compressors. Pilot‑circuit solenoid failure is one common source of unplanned load‑unload cycling trouble.
Frequently Asked Questions
Q1: Compressor cannot load / continuous blow‑‑‑down, should I directly order 7.1360.0 solenoid‑valve for replacement?
A: Not recommended to order blindly. Complete troubleshooting first: check controller output signal, coil supply‑voltage, pilot‑tubing carbon‑sludge clog. Many faults root in upstream circuit / piping instead of defective solenoid‑valve itself.
Q2: Same part‑number 7.1360.0, can different coil‑voltage versions interchange directly?
A: No. 7.1360.0 has multiple coil‑voltage variants (24VDC /110VAC /230VAC). Wrong voltage burns coil immediately. Submit old‑valve name‑plate photo to confirm coil‑spec before ordering.
Q3: Can I disconnect DIN43650 connector while compressor cabinet is powered‑on?
A: Strictly prohibited. Hot‑swap generates inductive surge, risks burning solenoid coil or Sigma‑Control controller IO‑port. Always perform full LOTO power‑cut before connector disassembly.
Q4: Can this 7.1360.0 solenoid‑valve be used for general‑purpose robot or food‑processing automation equipment?
A: No. This valve is designed as dedicated pilot control component for Kaeser screw compressor inlet‑valve / blow‑‑‑down sequence. It is not a general‑purpose industrial automation valve.
Q5: After installing new 7.1360.0 solenoid‑valve compressor still has pressure oscillation, is valve defective?
A: Not necessarily. Re‑check pilot‑tube sludge contamination, controller setting and inlet‑valve diaphragm wear condition. Fault may come from other pneumatic‑circuit components.
Q6: What damage situation is excluded from limited product warranty?
A: Limited warranty only covers manufacturing‑related defects of solenoid‑valve assembly. Excluded: coil burn‑out caused by wrong voltage, hot‑‑swap damage, spool sticking from oil‑sludge contamination, installation over‑torque mechanical damage; onsite labor and return‑shipment freight are not included.
Request Technical Quotation for 7.1360.0 Pilot Solenoid‑Valve
Fill inquiry‑form with compressor serial‑number, required coil‑voltage, fault‑description, quantity and destination‑country. Our sales‑engineer will reply quotation and lead‑time promptly.
Hot Tags: 7.1360.0 Pilot Solenoid Valve | Kaeser Screw Compressor Load‑Unload, China 7.1360.0 Pilot Solenoid Valve | Kaeser Screw Compressor Load‑Unload manufacturers, suppliers, 8 6494 0, 7 1360 0, Kaeser Thermostatic Valve, Kaeser Electronic Drain Valve, Kaeser Set, 7 1975 0